Electrical Braking of D.C Motor, Types

By
Last updated:

In practice it is often required to stop a unit driven by dc motors in an exact position or to have the speed of the driven unit suitably controlled during its deceleration. Such requirement is satisfactorily fulfilled by electric braking.

Types

  1. Regenerative braking
  2. Counter-current braking or plugging
  3. Dynamic braking

Regenerative Braking

Regenerative braking with return of energy to the supply circuit is obtained when under certain conditions the motor is forced to run at a speed higher that its no-load speed N0, due to which its Back emf Eb in the armature exceeds the applied voltage V.

Now the motor operates as a generator connected in parallel with the supply and the direction of the armature current also reverses so that energy is returned to the supply mains.

\mathrm{I}_{\mathrm{a}}=\frac{\mathrm{V}-\mathrm{E}_{\mathrm{b}}}{\mathrm{R}_{\mathrm{a}}}=\frac{-\mathrm{E}_{\mathrm{b}}-\mathrm{V}}{\mathrm{R}_{\mathrm{a}}}

With the reversal of direction of armature current the motor torque also reverses, braking torque is developed.

Figure shows speed-torque characteristics of dc shunt motor under regenerative braking condition.

Regenerative Braking

Here, it should be noted that the higher the armature circuit resistance, the higher the speed at which the motor has to run for a given braking torque.

Advantage

Regenerative braking is quite economical because the motor returns electrical energy to the supply mains.

Disadvantage

The application of regenerative braking is limited because most of the electrical drives are unable to satisfy the necessary condition N > N0.

Application

This method of braking is obtained by conveying, in hoisting equipment while lowering the load and also in certain special cases of speed control.

DC Series Motor

For dc series motor regenerative braking is not possible because with the reversal of direction of armature current, the direction of field excitation also reverses.

This method, is however used in traction drives with special arrangements.

Counter-Current Braking or Plugging

Counter-current braking or plugging occurs when the motor windings are connected for reverse direction of rotation at a time when the armature is still rotating in the forward direction either under the action of an external torque or due to inertia.

For plugging of motor reversal may be accomplished by reversing the polarity of the applied voltage either to the armature or to the field winding.

If the polarity of the voltage applied to the motor armature is reversed while it is still rotating in the initial direction, then the armature induced back emf Eb has the same polarity as before but the polarity of the input voltage V is reversed so that the armature circuit voltage can be written as

\begin{aligned} -V &=E_{b}+I_{a} R_{a} \\ I_{a} &=\frac{V+E_{b}}{R_{a}} \end{aligned}
Reversal of polarity of armature current produces a plugging torque which is given by
\begin{aligned} T_{p} &=K_{t} \phi I_{a} \\ &=-K_{t} \phi \frac{V+E_{b}}{R_{a}} \end{aligned}
The total braking torque at the instant of plugging is given by
Tbp = Tp + TL

where TL = load torque at the instant of plugging

Equation shows that at the instant of plugging the armature current becomes very large as both V and Eb have the same polarity at that instant. Hence, to limit the armature current during plugging it is necessary to insert suitable additional resistance in the armature circuit.

Counter - current Braking or Plugging
Counter – current Braking or Plugging

Figure (a and b) shows connection diagram for plugging and speed-torque characteristics of a dc shunt motor. Plugging is executed at a time when the motor is operating at the point E on characteristics A for a load torque TL as shown in figure (b).

Due to plugging the operating point shifts to point F on characteristics B as the speed of the motor cannot change instantaneously due to inertia. As a result of the braking, torque developed, the motor accelerates along characteristics B until the motor stops at G.

When the reversal of rotation is not required the supply must be switched off when the motor speed becomes very nearly equal to zero. If the supply is not switched off, then the motor will gain speed w opposite direction along GH characteristics B.

Note that as soon as the direction of rotation if reversed, the induced emf in the armature changes its polarity and again acts against the input voltage so that the drive will rotate in the reverse direction under motoring conditions.

At the point H the additional resistances are cut off from the armature circuit and hence, operating point shifts to point I on the natural characteristics C. The motor finally runs steadily in the reverse direction at the point J on the characteristics C for a load torque TL.

DC Series Motor

Figure shows connection diagram for plugging of dc series motor.

DC Series motor

For dc series motor also plugging can be accomplished by reversing the polarity of the voltage applied to the armature. However, it should be ensured that the current flowing in the field winding remains in the same direction as before when the armature current is reversed.

Figure shows speed-torque characteristics of dc motor under plugging.

D.C Series Motor

Dynamic Braking

Dynamic braking can be obtained by disconnecting the armature from supply and connecting an external resistance across the armature terminals. This method is also called rheostatic braking.

What is dynamic braking?

When an electric motor rotates, a kinetic energy is stored in its rotating mass. During dynamic braking the kinetic energy of the motor is converted into electric energy. This energy is dissipated in resistive elements.

DC Shunt Motor

Figure shows schematic arrangement for dynamic braking of d.c. shunt motor.

The field winding is left connected across the supply and it is undisturbed. The braking effect is controlled by varying the braking resistance rb.

Fig shows that the speed-torque characteristics of a dc shunt motor under dynamic braking conditions. It will be a straight line through the origin in the second quadrant as shown in figure.

Fig shows that the motor is operating steadily for a given load torque TL at the point A on its natural characteristics i.e, characteristics I when dynamic braking is executed. Due to braking the operating point shifts to B on the characteristics II from point A. The DC motor then decelerates along BO to standstill.

The slope of the braking characteristics can be controlled by varying the braking resistor rb.